Commissioning/Configuration
EP3356-0022
60
Version: 1.4
Variable
Meaning
Underrange
Measurement is below range
Overrange
Measuring range exceeded
Error
Collective error display
TxPDO Toggle
Toggles 0→1→0 with each updated data set
Value
Right-justified voltage value over the respective measuring range (Range of values
0x80.00.00.00…0…0x7F.FF.FF.FF)
Channel 1: supply voltage
Channel 2: bridge voltage
Distributed Clocks
In DC mode (Distributed Clocks) the process data x1A03
Timestamp
must be activated.
Also, the variables
DcOutputShift
and
DcInputShift
are displayed in the process data in DC mode. Upon
activation of the configuration these are calculated once in the unit [ns] on the basis of the set EtherCAT
cycle time (observe assigned task!) and DC shift times from the EtherCAT master settings. In the
InputBased
operating mode,
DcInputShift
indicates by how many nanoseconds [ns] before or after the global Sync the
box determines your process data. For further information on this, see the
Since the EP3356 is not DC-triggered but determines the timestamp itself, these values have no meaning in
the EP3356.