Mounting and Cabling
EP3356-0022
24
Version: 1.4
4.4
Resistor bridge
The EP3356 enables the connection of a resistor bridge or load cell in a 4-wire connection technology.
Fig. 15: Resistor bridge
The cable shield must be connected to pin 5 of the M12 connector.
The four M12 sockets of the EP3356 are internally connected to one another. Therefore, you can connect a
resistor bridge to any M12 socket.
You can also connect several resistor bridges in parallel:
.
The voltage U
ref
is 10 V and is generated in the EP3356 from U
P
.
Do not earth the sensor cable shield at the sensor end
If a shielded sensor cable is used, it should not be earthed at the sensor end. Otherwise measure-
ment deviations may occur in certain system configurations.