Parameter Description
Factory setting
EHC–05
Factory setting
SCB-10
AP073
Outdoor temperature: upper limit for heating
Can be set from 15 °C to 30.5 °C
not available
22
AP074
The heating is stopped. Hot water is maintained. Force Summer Mode
0 =Off
1 =On
not available
0
Tab.19 HP : Heat-pump Parameters = Heat pump parameters
Parameter Description
Factory setting
EHC–05
HP062
Hybrid electricity cost in high tarif
Can be set from 1 to 250
15
HP063
Hybrid electricity cost in low tarif
Can be set from 1 to 250
13
HP064
Cost of fossil energy (oil or gas) - price per litre or per m3
Can be set from 1 to 250
80
6.2.5
User \HMI menu
Tab.20 AP : Appliance Parameters = Appliance parameters
Parameter
Description
Factory setting
AP067
BKL backlighting
0 = off after 3 minutes of inactivity on the control panel
1 = on
0
AP103
Setting the LANGUAGE:
0 = no language
FR = French
NL = Dutch
EN = English
DE = German
ES = Spanish
IT = Italian
PL = Polish
PT = Portuguese
FR
AP104
Setting the CONTRAST:
Can be set from 0 to 3
3
AP105
Selecting the UNIT:
0 = °C
1 = °F
0
AP082
Changing the DLS summer/winter timer:
0 = off
1 = on
0
6.3
COUNTERS, TIME PROG, CLOCK menus
Tab.21 List of sub-menus
Sub-menu
Description
CNT
COUNTERS
DHW
Timer programming for the main domestic hot water circuit
CIRCA0
Timer programming for the main heating circuit CIRCA0 (EHC–05 PCB)
CIRCA1
Timer programming for the additional heating circuit according to the installation (SCB-10
PCB)
6 Settings
22
iHPI
7701562 - v02 - 22052018
Содержание AWHP 22 TR-2