Error code
Description
H02.60
The zone doesn't support the selected function
H06.01
Heat Pump Unit Failure occured
Heat pump outdoor unit fault
8.1.2
SCB-10 error codes
An error code is a temporary status, resulting from the detection of a heat
pump anomaly. The control panel attempts automatic restart of the heat
pump until it switches on.
When one of the following codes is displayed and the heat pump cannot
restart automatically, contact a maintenance technician.
Tab.36
Code
Description
H00.69
Buffer Tank temperature sensor is either removed or measures a temperature below range
H00.70
Buffer Tank temperature sensor is either shorted or measures a temperature above range
H00.71
Buffer Tank top temperature sensor is either removed or measures a temperature below range
H00.72
Buffer Tank top temperature sensor is either shorted or measures a temperature above range
H00.74
Buffer Tank temperature sensor was expected but not detected
H00.75
Buffer Tank Top temperature sensor was expected but not detected
H00.76
Cascade Flow temperature sensor is either removed or measures a temperature below range
H00.77
Cascade Flow temperature sensor is either shorted or measures a temperature above range
H00.78
Cascade Flow temperature sensor was expected but not detected
H02.02
Waiting For Configuration Number
H02.03
Configuration Error
H02.04
Parameter Error
H02.05
CSU does not match CU type
H02.16
Internal CSU Timeout
H02.36
Functional device has been disconnected
H02.40
Function unavailable
H02.45
Full Can Connection Matrix
H02.46
Full Can Device Administration
H02.47
Failed Connecting Function Groups
H02.48
Function Group Configuration Fault
H02.49
Failed Initialising Node
H02.53
OpenTherm ASK Error
H02.55
Invalid or missing device serial number
H02.61
Zone A doesn't support the selected function
H02.62
Zone B doesn't support the selected function
H02.63
Zone C doesn't support the selected function
H02.64
Zone D doesn't support the selected function
H02.65
Zone E doesn't support the selected function
H02.66
The anti corrosion protection (TAS) of the Domestic Hot Water tank is not connected
H02.67
The anti corrosion protection (TAS) of the Domestic Hot Water tank is shortend
H10.00
Flow temperature sensor Zone A Open
H10.01
Flow temperature sensor Zone A Closed
H10.02
Domestic Hot Water temperature sensor Zone A Open
H10.03
Domestic Hot Water temperature sensor Zone A Closed
H10.04
Swimming Pool Temperature Sensor Zone A Open
H10.05
Swimming Pool Temperature Sensor Zone A Closed
H10.09
Flow temperature sensor Zone B Open
H10.10
Flow temperature sensor Zone B Closed
H10.11
Domestic Hot Water Temperature Sensor Zone B Open
8 Troubleshooting
7701562 - v02 - 22052018
iHPI
37
Содержание AWHP 22 TR-2
Страница 48: ...7701562 v02 22052018 7701562 001 02 ...