8 Troubleshooting
8.1
Error messages
Resetting the control panel allows the appliance to be restarted.
The message
appears when a fault code is detected. After resolving
the problem, pressing the
key resets the appliance's functions and
thus eradicates the fault.
If several faults occur, they are displayed one after the other.
1. Reset the control panel by pressing the
key for 3 seconds,
when an error message is displayed.
In economy mode, the appliance will not run a domestic hot water
heating cycle after a central heating cycle.
2. Display the current operating status by briefly pressing the
key.
8.1.1
EHC–05 error codes
An error code is a temporary status, resulting from the detection of a heat
pump anomaly. The control panel attempts automatic restart of the heat
pump until it switches on.
When one of the following codes is displayed and the heat pump cannot
restart automatically, contact a maintenance technician.
Tab.35 List of temporary error codes
Error code
Description
H00.17
Domestic Hot Water tank temperature sensor is either shorted or measures a temperature
above range
H00.47
Heat pump flow temperature sensor is either removed or measures a temperature below
range
H00.48
Heat pump flow temperature sensor is either shorted or measures a temperature above range
H00.51
Heat pump return temperature sensor is either removed or measures a temperature below
range
H00.52
Heat pump return temperature sensor is either shorted or measures a temperature above
range
H00.57
Domestic Hot Water top temperature sensor is either removed or measures a temperature
below range
H00.58
Domestic Hot Water top temperature sensor is either shorted or measures a temperature
above range
H02.00
Reset In Progress
H02.02
Waiting For Configuration Number
H02.03
Configuration Error
H02.04
Parameter Error
H02.05
CSU does not match CU type
H02.07
Water Pressure Error active
Check the hydraulic pressure in the heating circuit.
H02.09
Partial blocking of the device recognized
BL input on the central unit PCB terminal block open
H02.10
Full blocking of the device recognized
BL input on the central unit PCB terminal block open
H02.23
System water flow error active
Flow problem
H02.25
Titan Active System short circuited or on an open circuit
H02.36
Functional device has been disconnected
No communication between the central unit PCB and the additional circuit PCB
H02.37
Uncritical device has been disconnected
No communication between the central unit PCB and the additional circuit PCB
Fig.43
MW
-5
0
0
0
0
6
1
-3
Fig.44
MW-5000060-3
8 Troubleshooting
36
iHPI
7701562 - v02 - 22052018