LED-PRO • User’s Guide
127
_K==oÉãçíÉ=`çåíêçä=mêçíçÅçä
Default IP Address
aÉÑ~ìäí=fm=^ÇÇêÉëë
The LED-PRO default IP address is
192.168.000.200
.
Please note:
•
The system returns to this value after a factory reset.
•
This default address can be changed using the menu system. In Chapter 4, refer
to the “
Ethernet
” section on page 89 for instructions.
opJOPO=jçÇÉ
The LED-PRO will respond with a “
#
” prompt when the command processor is ready for a
command. The command syntax is shown below
cmd arg1 arg2 … argn<CR>
Please note:
•
A space (ASCII 32) must be inserted between the command and any arguments
that follow. A space must also be inserted between all argument parameters,
except for the last argument in the chain.
•
All commands in RS-232 mode must be terminated with a carriage return (ASCII
13). The carriage return will tell the command processor to begin execution of the
command.
•
Query commands will return the following:
=result
#
The “=” indicates that a result from a query command is following. The “result” will
follow directly after the “=”. The value of the result will vary depending on the
query command used. A new line will be generated and the prompt (
#
) will
indicate the system is ready for a new command.
Table B-1.
RS-232 Command Syntax
Command
Description
cmd
Any valid graphics board command, typically 2 to 6 alphabetic (non numeric)
characters
arg
argument1, argument2, … argument"N" are required or optional parameters
depending on the command used.
<CR>
carriage return (ASCII 13) terminates the command
Содержание LED-PRO
Страница 1: ...r d ibaJmol Manual 26 0501000 00 Revision B qj...
Страница 14: ...xiv LED PRO User s Guide Table of Contents...
Страница 38: ...24 LED PRO User s Guide 3 Installation Format Connection Table...
Страница 124: ...110 LED PRO User s Guide 4 Operation Using the Input Position Menu...
Страница 174: ...160 LED PRO User s Guide _K o m LED PRO Remote Commands...
Страница 186: ...172 LED PRO User s Guide Index v YUV 15 16 w Zoom 97 ZOOM nnn n 159...