![Banner iVu Plus BCR Gen2 Series Скачать руководство пользователя страница 85](http://html1.mh-extra.com/html/banner/ivu-plus-bcr-gen2-series/ivu-plus-bcr-gen2-series_instruction-manual_4021075085.webp)
4. Set Trigger to Command. Go to Main Menu > Imager > Trigger , and from the drop-down list select Command.
5. Issue a trigger command as follows:
>>
do trigger
\x0D\x0A
<<
OK\x0D\x0A
6. Check that the inspection passed.
>>
get inspection status
\x0D\x0A
<<
OK\x0D\x0A
<<
Pass\x0D\x0A
7. Get the barcode data read by the iVu sensor.
>>
get bcr_result
\x0D\x0A
<<
OK\x0D\x0A
<<
"0043000011201"x0D\x0A
How to Modify Barcode Compare Data Using the Command Channel
1. Go to Main Menu > System > Sensor Configuration > Serial I/O.
2. Click Channel Mode.
3. In the Channel Mode dialog, select Command from the drop-down list.
4. Set Trigger to Command. Go to Main Menu > Imager > Trigger , and from the drop-down list select Command.
5. Set the compare data.
>>
set bcr_input comparedata "0043000011201"
\x0D\x0A
<<
OK\x0D\x0A
6. Trigger the sensor.
>>
do trigger
\x0D\x0A
<<
OK\x0D\x0A
7. Check that the inspection passed.
>>
get inspection status
\x0D\x0A
<<
OK\x0D\x0A
<<
Pass\x0D\x0A
iVu Plus BCR Gen2 Series Sensor
www.bannerengineering.com - Tel: + 1 888 373 6767
85