Figure 133. Drag to Connect
The connection is made.
9. Double-click the iVu BCR icon to open the Device window.
10. Select the desired modules or submodules from the Hardware catalog and drag them onto the Device overview tab
on the Device view tab.
The iVu BCR device is configured.
Changing the Device IP Address
Use these instructions to change the IP address of the iVu BCR device, using the Siemens TIA Portal (v13) software. Use
these instructions as a basis if you are using another controller (PLC).
1. Start the Siemens TIA Portal (v13) software.
2. Click Open existing project.
3. Select a project an open it.
4. Click Devices & networks after the project has been uploaded to go to Network view.
Figure 134. Network View
Network View displays.
5. Double-click on the iVu BCR icon to open the Device view.
6. Click on the iVu BCR icon in the graphic area of the Device view to open the Module properties window.
The module can now be configured.
7. Click Properties.
8. Click General.
9. Select PROFINET interface > Ethernet addresses.
Figure 135. Ethernet Addresses
10. Select Set IP address in the project.
iVu Plus BCR Gen2 Series Sensor