Numeric ID
Text ID
Description
10350
ARGUMENTS_DETECTED
Get command received with unneeded arguments
10351
INVALID_ARGUMENT_TYPE
Item ID specified must be an item (not a group or method)
10500
DATA_SET_EMPTY
Data export operation returned no results.
10900
SENSOR_NOT_READY
Command specified requires iVu BCR to be in the READY state.
10920
SENSOR_TYPE_NOT_ACTIVE
Command specified belongs to a different sensor type.
10950
DEVICE_TYPE_INVALID
Command not supported on this device type.
15000
VALUE_INVALID
Text value is invalid / unknown
15050
VALUE_INVALID
Text value is invalid - expecting True or False
15100
STRING_TOO_LONG
String value specified exceeds maximum allowable length
20002
COMPARE_DATA_DISABLED
Operation requires Barcode compare to be enabled
20003
COMPARE_MASK_INVALID
Compare mask invalid. Expecting string of 1's and 0's with length
equal to compare data string
20004
NUMBER_TO_FIND_NOT_ONE
Barcode number to find must be set to one for this operation.
20005
COMPARE_MASK_DISABLED
Operation requires Barcode compare mask to be enabled.
80000
REMOTE_DISPLAY_NOT_CONNECTED
Remote Display must be connected to obtain this value
80001
REMOTE_DISPLAY_NOT_SUPPORTED
This device does not have Remote Display capability
80100
COMMAND_MODE_EXPECTED
The Trigger Mode must be set to "Command" perform this
operation
80101
COMMAND_TIMED_OUT
The command timed out before finishing
80102
TRIGGER_REQUIRED
Access to the specified data requires a triggered inspection
80150
COMMAND_TIMED_OUT
The command timed out before finishing
80200
SYSTEM_ERROR_NOT_ACTIVE
The System Error must be active to execute this command
80350
MULTIPLE_INSPECTIONS_DISABLED
Requires multiple inspections to be enabled
80351
MULTIPLE_INSPECTIONS_EMPTY
No inspections are available in multiple inspection mode.
80400
PRODUCT_CHANGE_WHEN_NOT_READY
Sensor must be in the READY state to perform a product change.
80401
PRODUCT_CHANGE_INVALID_INSPECTION
Attempt to product change to an unknown or invalid inspection.
80402
PRODUCT_CHANGE_TIMEOUT
The Product Change operation timed out.
80403
PRODUCT_CHANGE_TO_SAME_INSPECTION
Attempt to product change to the same inspection.
80404
SENSOR_NAME_NOT_FOUND
Attempt to use a command without a sensor name in a multi-
sensor inspection
Examples of Operation
The following examples show how to utilize the iVu BCR Command Channel via the Industrial Ethernet connection.
Clear System Error
1. Write the number
81
as a 16-bit integer into the Command ID register.
2. Toggle the Command bit from 0 to 1 (bit 15 in the Input Bits/Input Coil Bits register).
3. Wait for the Command ACK flag to go from 0 to 1 (bit 15 in the Input Bits ACK/Input Coil Bits ACK register).
4. Verify that the Execution Error flag is not set (that is, the value should be 0). This is bit 15 in the Output Bits/Status
Coil Bits register. If the value is 1, read the Error Code register for more information.
5. Task Complete. Toggle the Command bit back to 0 (bit 15 in the Input Bits/Input Coil Bits register).
Get/Set Trigger Mode
Get the current Trigger Mode from the iVu BCR.
iVu Plus BCR Gen2 Series Sensor
www.bannerengineering.com - Tel: + 1 888 373 6767