146
BVS HS-Q Series
Standard Hand Held Barcode Reader
Enter/Exit Programming Mode
4
Configuration Using Barcodes
Codabar Set Length 1
This feature specifies one of the barcode lengths for
Codabar Length Control on page 145Cod-
abar Length Control on page 145
. Length 1 is the minimum label length if in
variable length decoding, a minimum and maximum length may be set. on page 231
Mode, or the
first fixed length if in
Fixed Length: For fixed length decoding, two different lengths may be set. on
Mode. Length includes the barcode’s start, stop, check and data characters. The
length must include at least one data character. The length can be set from 3 to 50 characters.
Table Codabar Length 1 Setting Examples
provides some examples for setting Length 1. See
for detailed instructions on setting this feature.
Codabar Length
1 Setting
Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
(and pad with
leading zeroes)
03 Characters
09 Characters
15 Characters
50 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODABAR LENGTH 1 SETTING
4
Scan Two
Characters
From
‘0’ and ‘3’
‘0’ and ‘9’
‘1’ and ‘5’
‘5’ AND ‘0’
5
Scan ENTER/EXIT PROGRAMMING MODE
$CCBL1
Select Codabar Length 1 Setting
Make a mistake? Scan the CANCEL barcode
to abort and not save the entry string. You can
then start again at the beginning.
~
CANCEL
DEFAULT
03 = Length 1 is 3 Characters