147
www.balluff.com
BVS HS-Q Series
Standard Hand Held Barcode Reader
Enter/Exit Programming Mode
4
Configuration Using Barcodes
Codabar Set Length 2
This feature specifies one of the barcode lengths for
Codabar Length Control on page 145Cod-
abar Length Control on page 145
. Length 2 is the maximum label length if in
variable length decoding, a minimum and maximum length may be set. on page 231
Mode, or the
second fixed length if in
Fixed Length: For fixed length decoding, two different lengths may be set.
Mode. The length includes the barcode’s start, stop, check and data characters.
The length must include at least one data character.
The length can be set from 3 to 50 characters. A setting of 0 specifies to ignore this length (only
one fixed length).
Table Codabar Length 2 Setting Examples
provides examples for setting Length 2. See
for detailed instructions on setting this feature.
Codabar Length
2 Setting
Examples
STEP
ACTION
EXAMPLES
1
Desired
Setting (and
pad with
leading zeroes)
00 Ignore
This Length
07 Characters
15 Characters
50 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODABAR LENGTH 2 SETTING
4
Scan Two
Characters
From
‘0’ and ‘0’
‘0’ and ‘7’
‘1’ and ‘5’
‘5’ AND ‘0’
5
Scan ENTER/EXIT PROGRAMMING MODE
$CCBL2
Select Codabar Length 2 Setting
Make a mistake? Scan the CANCEL barcode
to abort and not save the entry string. You can
then start again at the beginning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters
Содержание BVS HS-QB-SDR-MA-02-02
Страница 1: ...Balluff BVS HS Q Family Standard Handheld Barcode Reader Operation Manual english...
Страница 282: ...282 BVS HS Q Series Standard Hand Held Barcode Reader 9 Appendix D Keypad A B C D E F...
Страница 295: ...295 www balluff com BVS HS Q Series Standard Hand Held Barcode Reader NOTES...