System functions (continued)
System Status Since POR
The
System Status Since POR
shows the result of the
System Monitor
function. It can be used without any
restriction. If an error is detected, the LED turns red. If the
bit is set because of an error, it can not be cleared until the
next power-on reset.
7.11.4 System commands
Command
Value
Device Action
0x810 (128)
Device Reset
– Resets
System Status
Actual
to zero.
0x81 (129)
Application Reset
– Resets
System
Status Actual
to zero.
0x82 (130)
Restore Factory Settings
– Resets
System Status Actual
to zero.
0x83 (131)
Back-to-Box Reset
– Resets
System
Status Actual
to zero.
0xA5 (165)
Maintenance Reset
– Resets
System
Status Actual
to zero.
Tab. 7-38: System Monitor – System commands
957946_AA ∙ EN ∙ C24 ; subject to modification.