42
english
In Tab. 4-1 the basic IO-Link specification of the standard
variant BMC R16E-004-…-01,5-S4 is described.
Specification
IO-Link Description
Value
Transmission rate
COM
COM3 (230.4 kBaud)
Minimum cycle time of device
min cycle time
4 ms
Frame specification:
M-sequence capability:
0×1B
– Amount of
Preoperate
on demand data
required
– Number of On-demand Data in
Preoperate
2 bytes
– Amount of
Operate
on demand data required
– Number of On-demand Data in
Operate
32 bytes
– ISDU
– ISDU supported
Supported
IO-Link protocol version
Revision ID
0×11 (Version 1.1)
Amount of process data from the device to the
master
ProcessDataIn
32 bytes
Amount of process data from the master to the
device
ProcessDataOut
3 bytes
Manufacturer ID
Vendor ID
0×378
Device identification
Device ID
0x0E0104 (BCM R16E-…-CI02-…)
0x0E0103 (BCM R16E-…-CI01-…)
Tab. 4-1: Communication parameters
4
Communication parameters
BCM R16E-004-CI0 _ - _ _ , _-S4
Condition Monitoring Sensor
Содержание BCM R16E-004-CI01-S4 Series