www.balluff.com
95
english
5.4.5 System commands
Command Value
Device Action
0x80 (128)
Device Reset
Resets the following to 0:
PD X Band 1, …, PD X Band 27
PD Scaler X
PD Y Band 1, …, PD Y Band 27
PD Scaler Y
PD Z Band 1, …, PD Z Band 27
PD Scaler Z
PD Alarm X Band 1, …, PD Alarm X Band 8
PD Alarm Y Band 1, …, PD Alarm Y Band 8
PD Alarm Z Band 1, …, PD Alarm Z Band 8
PD Alarm Band 1, …, PD Alarm Band 8
PD Scaler X 1-3
PD Scaler X 4-6
PD Scaler X 7-9
PD Scaler X 10-12
PD Scaler X 13-15
PD Scaler X 16-18
PD Scaler X 19-21
PD Scaler X 22-24
PD Scaler X 25-27
for axis Y and Z als well
PD Envelope X Band 1, …, PD Envelope X Band 6
PD Envelope Scaler X 1-3
PD Envelope Scaler X 4-6
for axis Y and Z als well
Envelope X Band 1 RMS, …
,
Envelope X Band 6 RMS
Envelope Y Band 1 RMS, …
,
Envelope Y Band 6 RMS
Envelope Z Band 1 RMS, …
,
Envelope Z Band 6 RMS
Spectrum Acquisition Time
Spectrum Resolution
Envelope Spectrum Acquisition Time
Envelope Spectrum Resolution
Resets invalid to 1.
0x81 (129)
Application Reset
Resets the following to firmware defaults:
ALARM DELAY
HOLD UP TIME
DELAY START MONITORING
Spectrum Configuration
Spectrum Band Mode
Spectrum Absolute Band Limits
Spectrum Rotational Speed Multipliers
Spectrum Band Alarm Configuration
Envelope Spectrum Configuration
Envelope Spectrum Band Mode
Envelope Spectrum Absolute Band Limits
Envelope Spectrum Rotational Speed Multipliers
5
Primary device functions (continued)
BCM R16E-004-CI0 _ - _ _ , _-S4
Condition Monitoring Sensor
Содержание BCM R16E-004-CI01-S4 Series
Страница 2: ...www balluff com...
Страница 3: ...BCM R16E 004 CI01 _ _ _ S4 BCM R16E 004 CI02 _ _ _ S4 Konfigurationsanleitung deutsch...
Страница 4: ...www balluff com...
Страница 165: ...BCM R16E 004 CI01 _ _ _ S4 BCM R16E 004 CI02 _ _ _ S4 Configuration guide english...