www.balluff.com
17
english
Name
Index
Sub-
index
Access
Length
Data Type
Data
Storage
Default
Vibration Acceleration
RMS Maxima
0x2171
(8561)
0
RO
48 bytes
ArrayT
–
Maximum a-RMS
Since Startup X
1
RO
4 bytes
FLOAT32
n/a
–
Maximum a-RMS
Since Startup Y
2
RO
4 bytes
FLOAT32
n/a
–
Maximum a-RMS
Since Startup Z
3
RO
4 bytes
FLOAT32
n/a
–
Maximum a-RMS
Since Startup M
4
RO
4 bytes
FLOAT32
n/a
–
Maximum a-RMS
Custom X
5
RO
4 bytes
FLOAT32
n/a
–
Maximum a-RMS
Custom Y
6
RO
4 bytes
FLOAT32
n/a
–
Maximum a-RMS
Custom Z
7
RO
4 bytes
FLOAT32
n/a
–
Maximum a-RMS
Custom M
8
RO
4 bytes
FLOAT32
n/a
–
Maximum a-RMS
Lifetime X
9
RO
4 bytes
FLOAT32
n/a
–
Maximum a-RMS
Lifetime Y
0A
RO
4 bytes
FLOAT32
n/a
–
Maximum a-RMS
Lifetime Z
0B
RO
4 bytes
FLOAT32
n/a
–
Maximum a-RMS
Lifetime M
0C
RO
4 bytes
FLOAT32
n/a
–
Vibration Severity Zone
Configuration
0x2165
(8549)
0
RW
12 bytes
ArrayT
Yes
12500
Min.: 0, Max.: 12500
Severity Zone
Boundary A/B
1
RW
4 bytes
FLOAT32
No
12500
Min.: 0, Max.: 12500
Severity Zone
Boundary B/C
2
RW
4 bytes
FLOAT32
No
12500
Min.: 0, Max.: 12500
Severity Zone
Boundary C/D
3
RW
4 bytes
FLOAT32
No
12500
Min.: 0, Max.: 12500
3
Overview of IO-Link data and functions (continued)
BCM R16E-004-CI0 _ - _ _ , _-S4
Condition Monitoring Sensor
Содержание BCM R16E-004-CI01-S4 Series
Страница 2: ...www balluff com...
Страница 3: ...BCM R16E 004 CI01 _ _ _ S4 BCM R16E 004 CI02 _ _ _ S4 Konfigurationsanleitung deutsch...
Страница 4: ...www balluff com...
Страница 165: ...BCM R16E 004 CI01 _ _ _ S4 BCM R16E 004 CI02 _ _ _ S4 Configuration guide english...
Страница 166: ...www balluff com...