www.baldormotion.com
8-4 Specifications
MN1942
8.1.5 Digital inputs - drive enable and DIN0 general purpose (X3)
Unit
All models
Type
Opto-isolated inputs
Input voltage
Nominal
Minimum
Maximum
Active
Inactive
VDC
24
12
30
> 12
< 2
Input current
(maximum, per input)
mA
50
Sampling interval
ms
1
Minimum pulse width
μ
s
5
8.1.6 Digital inputs DIN1, DIN2 - high speed general purpose (X3)
Unit
All models
Type
Opto-isolated inputs
Input voltage
Nominal
Minimum
Maximum
Active
Inactive
VDC
24
12
30
> 12
< 2
Input current
(maximum, per input)
mA
20
Maximum input frequency
MHz
1
Minimum pulse width
ns
250
8.1.7 Digital outputs DOUT0, DOUT1 - status and general purpose (X3)
Unit
All models
User supply
(maximum)
V
28
Output current
(max. continuous)
mA
100
Fuse
Approximate trip current
Reset time
mA
s
200
<20
Update interval
ms
1