www.baldormotion.com
6-22 Configuration
MN1942
6.4.8 Performing test moves - relative positional move
This section tests the basic operation of the drive and motor by performing a positional move.
Note:
To stop a move in progress, click the red stop button or the drive enable button on
the toolbar. Alternatively, use the Mint WorkBench ‘Red Stop Button’ feature.
1. Check that the Drive enable button is
pressed (down).
2. In the Toolbox, click the Edit & Debug icon.
3. Click in the Command window.
4. Type:
MOVER(0)=10
GO(0)
This will cause the motor to move to a
position 10 units from its current position.
The move will stop when completed.
5. If you have finished testing click the Drive
Enable button to disable the drive.