www.baldormotion.com
6-24 Configuration
MN1942
6.5.1.3 Fine-tuning - Current tab
The Current tab allows you to set current loop gains and perform test moves. The
Commissioning Wizard may have already set some of these values, depending on the type of
system selected on the mode screen. Normally, it should not be necessary to alter these values.
Enter new values in the required boxes and then click
Apply
to download the values to the
MicroFlex
e
100. To perform tests, go to the Test Parameters area at the bottom of the tab. Enter
test values and then click
Go
to perform the test move. If you need help, just press F1 to display
the help file.
The additional
Measure
and
Feedback alignment
buttons can be used to repeat the same
measurement and alignment tests that are used by the Commissioning Wizard.
6.5.1.4 Fine-tuning - SRamp / Simple SRamp tabs
The SRamp and Simple SRamp tabs allow you to set parameters and perform test moves using
S-ramped profiles. These profiles cause the normal trapezoidal move profile to be modified to
create smoother acceleration and decleration.
Enter new values in the required boxes and then click
Preview
to see an example of the intended
move profile. Click
Go
to perform the test move. If you need help, just press F1 to display the help
file.
6.5.1.5 Fine-tuning - Filter tab
The Filter tab allows you to set the properties of the MicroFlex
e
100’s two torque filters. It should
only be necessary to use the torque filters if there is a particular problem with resonant
frequencies in the load.
Enter new values in the required boxes and then click
Apply
to download the values to the
MicroFlex
e
100. To perform tests, go to the Frequency Response Params area at the bottom of
the tab. Enter test values and then click
Go
to perform the test move. If you need help, just press
F1 to display the help file.
6.5.1.6 Fine-tuning - Flux tab
The Flux tab allows you to set gains and perform test moves when using induction motors.
Enter new values in the required boxes and then click
Apply
to download the values to the
MicroFlex
e
100. Click
Go
to perform the test move. If you need help, just press F1 to display the
help file.
Содержание MicroFlex e100
Страница 1: ......
Страница 2: ......
Страница 14: ...www baldormotion com 2 4 Introduction MN1942...
Страница 80: ...www baldormotion com 5 26 Input Output MN1942...
Страница 108: ...www baldormotion com 6 28 Configuration MN1942...
Страница 116: ...www baldormotion com 7 8 Troubleshooting MN1942...
Страница 124: ...www baldormotion com 8 8 Specifications MN1942...
Страница 142: ...www baldormotion com B 6 Control System MN1942...
Страница 170: ...Comments MN1942 Thank you for taking the time to help us...
Страница 171: ......
Страница 172: ......