Basic Installation 3-11
MN1942
3.4 Power connections
This section provides instructions for connecting the AC power supply.
The installer of this equipment is responsible for complying with NEC (National Electric Code)
guidelines or CE (Conformite Europeene) directives and application codes that govern wiring
protection, earthing/grounding, disconnects and other current protection.
Electrical shock can cause serious or fatal injury. Do not touch any power
device or electrical connection before you first ensure that power has been
disconnected and there is no high voltage present from this equipment or other
equipment to which it is connected.
MicroFlex
e
100 drives are designed to be powered from standard single and three-phase lines
that are electrically symmetrical with respect to earth/ground. The power supply module within
all MicroFlex
e
100 models provides rectification, smoothing and current surge protection. Fuses
or circuit breakers are required in the input lines for cable protection.
Note:
A Residual Current Device (RCD) must not be used for fusing the drive.
An appropriate type of circuit breaker or fuse must be used.
All interconnection wires should be in metal conduits between the MicroFlex
e
100, AC power
source, motor, host controller and any operator interface stations. Use UL listed closed loop
connectors that are of appropriate size for the wire gauge being used. Connectors are to be
installed using only the crimp tool specified by the manufacturer of the connector.
3.4.1 Earthing / grounding
A permanent earth/ground bonding point is provided on the heatsink, which must be used as the
protective earth. It is labeled with the protective earth symbol in the casting and does not form any
other mechanical function.
Connector X1 contains earth terminals, but these must not be used as protective earth since the
connector does not guarantee earth connection first, disconnection last. Earthing methods are
shown in section 3.4.2.
Note:
When using unearthed/ungrounded distribution systems, an isolation transformer
with an earthed/grounded secondary is recommended. This provides three-phase
AC power that is symmetrical with respect to earth/ground and can prevent
equipment damage.
3.4.1.1 Protection class
User protection has been achieved using Protective Class
I
(EN61800-5-1, 3.2.20), which
requires an earth connection to the unit whenever hazardous voltages are applied. The
equipment provides protection against electric shock by:
H
Means of connection of protective earth to accessible live conductive parts.
H
Basic insulation.
3.4.1.2 Earth leakage
Maximum earth leakage from the MicroFlex
e
100 is 3.4 mA per phase (230 V, 50 Hz supply).
This value does not include the earth leakage from the AC power filter, which could be much
larger (see section A.1.4). If the MicroFlex
e
100 and filter are mounted in an enclosure, it is
recommended the enclosure is earthed using a 10 mm
2
conductor.
WARNING
Содержание MicroFlex e100
Страница 1: ......
Страница 2: ......
Страница 14: ...www baldormotion com 2 4 Introduction MN1942...
Страница 80: ...www baldormotion com 5 26 Input Output MN1942...
Страница 108: ...www baldormotion com 6 28 Configuration MN1942...
Страница 116: ...www baldormotion com 7 8 Troubleshooting MN1942...
Страница 124: ...www baldormotion com 8 8 Specifications MN1942...
Страница 142: ...www baldormotion com B 6 Control System MN1942...
Страница 170: ...Comments MN1942 Thank you for taking the time to help us...
Страница 171: ......
Страница 172: ......