![Azbil Micro Flow MQV0002 Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/azbil/micro-flow-mqv0002/micro-flow-mqv0002_user-manual_3042628049.webp)
5-3
Chapter 5. ADVANCED OPERATION
Function setup items
The following table shows the function setup items:
Display Item
Item Description
Setup Item and Description
Factory
Setting
Remarks
C-0
1
Key lock
0: Key lock disabled
1: Settings other than flow rate
setting (SP) are key-locked
2: All settings are key-locked
0
The key lock can be cancelled even
while it is enabled.
When an attempt is made to change
a key-locked setting,
LOc.
is indicated
on the display.
C-02
RUN key operation
and operation
mode selection
when power
turned ON
0: RUN key disabled (Operation
starts in the control mode
when the power is turned ON)
1: RUN key enabled (1)
(Operation is started up in the
operating mode used before
power shutdown when the
power is turned ON)
2: RUN key enabled (2)
(Operation is started up in the
fully closed mode when the
power is turned ON)
1
Determines whether or not the
operating mode is changed (fully
closed/control/fully open) by the RUN
key. Additionally, the operating mode
at power ON can be selected.
For how to select the operating
mode:
C-03
Flow rate setup
method
(SP setup method
selection)
0: Digital setup (set
by key operation or
communications)
1: Analog setup (set by external
analog input voltage)
0
*1
C-04
Number of flow
set value
(number of SPs
selection)
0: Number of SPs = 1
(
SP-0
only)
1: Number of SPs = 2
(
SP-0
,
SP-
1
)
2: Number of SPs = 3
(
SP-0
to
SP-2
)
3: Number of SPs = 4
(
SP-0
to
SP-3
)
4: Number of SPs = 5
(
SP-0
to
SP-4
)
5: Number of SPs = 6
(
SP-0
to
SP-5
)
6: Number of SPs = 7
(
SP-0
to
SP-6
)
7: Number of SPs = 8
(
SP-0
to
SP-7
)
0
How to switch the SP number using
external contact input and external
3-way switching input:
C-05
Input range
selection of
analog setup
(analog SP input
range selection)
(1) Analog output selection is
set at voltage output
(
C-06
= 0, 1, 4, or 5).
0: 0 to 5 V internal reference
input
1: 0 to 5 V external reference
input
2: 1 to 5 V external reference
input
(2) Analog output selection is
set at current output
(
C-06
= 2, 3, 6, or 7)
0: 0 to 20 mA external reference
input
1: 0 to 20 mA external reference
input
2: 4 to 20 mA external reference
input
1
Internal reference 0 to 5 V input is
the setting to use the 5 V-reference
voltage from this device when
inputting a voltage with the optional
potentiometer (variable change
resistor with dial). Using this method,
no external power supply for setup is
needed.
The voltage input/current input is
automatically selected as it is linked
with the set value of
C-06
:
Table in Note
*2
*2
,