![Azbil Micro Flow MQV0002 Скачать руководство пользователя страница 80](http://html1.mh-extra.com/html/azbil/micro-flow-mqv0002/micro-flow-mqv0002_user-manual_3042628080.webp)
7-12
Chapter 7. SPECIFICATIONS
Note
•
The setup and display resolutions described above can be improved by reducing
the flow rate range using flow rate range setup
C-24
or
C-25
.
A still higher resolution can be set using the analog setup (
C-03
= 1). For more
information,
5 - 4 Flow Rate Range Change Function and Settings and
Display Resolutions After Change of Range (P. 5-17)
Relationship between differential pressure and flow rate
Condition: the valve is fully open in air.
z
MQV9005/9020
0
10
20
30
40
50
60
0
10
30
20
40
50
60
Differential pressure [kPa]
Flo
w r
at
e [mL/min(standar
d)]
(1)
(2)
(3)
(4)
Outlet pressure condition
(1) 150 kPa(gauge)
(2) 50 kPa(gauge)
(3) 0 kPa(gauge)
(4) –50 kPa(gauge)
z
MQV9200/9500/0002
0
10
20
30
40
50
60
0
40
120
80
160
200
240
Differential pressure [kPa]
Flo
w r
at
e [mL/min(standar
d)]
0
2
4
6
8
10
0.0
0.2
0.4
0.6
0.8
1.0
Differential pressure [kPa]
Flo
w r
at
e [L/min(standar
d)]
0
10
20
30
40
50
60
0.0
0.4
0.8
1.2
1.6
2.0
2.4
Differential pressure [kPa]
Flo
w r
at
e [L/min(standar
d)]
MQV0002
MQV9200
MQV9500
Outlet pressure condition
(1) 150 kPa(gauge)
(2) 50 kPa(gauge)
(3) 0 kPa(gauge)
(4) –50 kPa(gauge)
Outlet pressure condition
(1) 150 kPa(gauge)
(2) 50 kPa(gauge)
(3) 0 kPa(gauge)
(4) –50 kPa(gauge)
Outlet pressure condition
(1) 150 kPa(gauge)
(2) 50 kPa(gauge)
(3) 0 kPa(gauge)
(4) –50 kPa(gauge)
(1)
(2)
(3)
(4)
(1)
(2)
(3)
(4)
(1)
(2)
(3)
(4)
z
MQV0005/0020/0050(B, C)
0
10
20
30
40
50
60
0
4
12
8
16
20
24
MQV0020
(1)
(2)
(3)
(4)
0
2
4
6
8
10
0
2
4
6
8
10
MQV0005
(1)
(2)
(3)
(4)
0
20
40
60
80
100
120
0
10
20
30
40
50
60
MQV0050(B, C)
(1)
(2)
(3)
(4)
Differential pressure [kPa]
Flo
w r
at
e [L/min(standar
d)]
Differential pressure [kPa]
Flo
w r
at
e [L/min(standar
d)]
Differential pressure [kPa]
Flo
w r
at
e [L/min(standar
d)]
Outlet pressure condition
(1) 150 kPa(gauge)
(2) 50 kPa(gauge)
(3) 0 kPa(gauge)
(4) –50 kPa(gauge)
Outlet pressure condition
(1) 150 kPa(gauge)
(2) 50 kPa(gauge)
(3) 0 kPa(gauge)
(4) –50 kPa(gauge)
Outlet pressure condition
(1) 150 kPa(gauge)
(2) 50 kPa(gauge)
(3) 0 kPa(gauge)
(4) –50 kPa(gauge)