![Azbil Micro Flow MQV0002 Скачать руководство пользователя страница 87](http://html1.mh-extra.com/html/azbil/micro-flow-mqv0002/micro-flow-mqv0002_user-manual_3042628087.webp)
7-19
Chapter 7. SPECIFICATIONS
•
Separate display unit
Unit: mm
OK
SP
PV
m
3
Digital
Mass Flow
Controller
L/ min
ALM EV1 EV2
RUN
ENT
DISP
88
45.8
29.3
1.6
38
33
105
93
5
4.5
12.5
M4(2)
6
19
(R)
Mounting panel cutout dimensions (recommended)
100
±
0.2
50
±
0.2
45
±
0.2
90
±
0.2
35
±
0.2
17.5
±0.2
z
Cable for connecting display to main unit
Unit: mm
2000 min.
Oki Electric Cable Company, Limited FLEX-S16-7/0.127-2651P
Color: pin No.1, red; pin Nos. 5, 10 and 15, green; others, gray
Red
HIROSE ELECTRIC CO., LTD. HIF3BA-16D-2.54R