1-9
Chapter 1. INTRODUCTION
z
MQV0050(J, K)/0200/0500
Basic
model
No.
Standard
control
flowrate
range
Display
Material of
gascontacting
parts
Connection
method
Gas
type
Optional
functions
Appended
No.
Description
1 2 3 4 5
MQV
Digital mass flow controller, MQV
0050
0.4 to 50.0 L/min (standard)
*1, *4, *6
0200
2 to 200 L/min (standard)
*1, *4
0500
4 to 500 L/min (standard)
*1, *4
J
Integrated display (body length 150 mm)
K
Separate display (body length 150 mm)
S
SUS316
R
Rc 1/2"
S
1/2" Swagelok
V
1/2" VCR
U
3/4-16UNF
N
Air, nitrogen
*2, *4
S
Oxygen
*3, *4
0
Without optional functions
0
Without optional functions
1
Model with RS-485 communications
(CPL) function
0
Without optional functions
0
Without optional functions
1
Gas-contacting parts treated to be oil
free
*5
0
Without optional functions
D
With inspection certificate
Y
With traceability certificate
0
Product version
*1. The notations mL/min (standard) and L/min (standard) indicate the volume flow rate per minute converted to 20 ˚C,
one atmosphere (101.3 kPa (abs)). The reference temperature can also be changed to 0 ˚C, 25 ˚C or 35 ˚C.
*2. Air/nitrogen is the factory setting. By changing the setting, this model can be used for argon, carbon dioxide (CO
2
),
city gas 13A (LNG: 46 MJ/m
3
), city gas 13A (LNG: 45 MJ/m
3
), propane 100 %, methane 100 %, or butane 100 %.
Additionally, semi-standard gas models that can be used for ammonia or acetylene (seal material: EPDM) can also be
manufactured. (MQV0200/0500 only)
*3. Oxygen is the factory setting. By changing the setting, this model can be used for air/nitrogen, argon, carbon dioxide
(CO
2
), city gas 13A (LNG: 45 MJ/m
3
), propane 100 %, methane 100 %, or butane 100 %. However, once this device has
been used for a gas other than oxygen, never reuse it for oxygen.
*4. The flow rate ranges in the above table are for use of this device for air. The controllable flow range may vary
depending on the type of gas.
Gas type and control range (P. 7-11).
*5. When oxygen is selected as the gas type, selection “1,” “gas-contacting parts treated to be oil free,” must be selected
for Optional function 4.
*6. The MQV0050(J, K) is for low differential pressure and is controllable to a high flow rate range with lower differential
pressure than the MQV0050(B, C).