![axing MK 12-0 N Series Скачать руководство пользователя страница 96](http://html1.mh-extra.com/html/axing/mk-12-0-n-series/mk-12-0-n-series_operation-instructions-manual_3036761096.webp)
Operation instructions | MK 8-0x | MK 16-0x | MK 8-2x | MK 8-0xN | MK 12-0xN
20
2022-07-27 | Technical improvements, changes in design, printing- and other errors reserved.
3.2.
Front page
The relevant information required for the function of the system are shown on the front page. The decisive
thing is the quality of the signals at the INPUT and the utilization of the modulators at the OUTPUT.
3.2.1.
Input
The bit error rate BER of all tuners is shown on the left side. The amount of bit errors for the last 1,000,000
transferred bits is calculated.
Also the LEVEL and the C/N ratio are shown.
3.2.2.
Outputs
The fill level of all modulators is shown. 100% modulator fill level correspond to the maximal net data rate of
the output channel.
If the current fill level exceeds the maximal fill level, it may cause image disturbances, e.g. mosaic images.
The data rates of the programs are not constant. They are dynamically changed by the sender. To ensure an
undisturbed reception, a reserve must absolutely be observed.
We recommend you to set the maximal fill level to 90%.
From a fill level of 95%, this is indicated in red.
The number of choosen programs (see 4.2 on page 25) and the configuration of the modulators (see 4.3 on
page 37) have an influence to the fill level.