![axing MK 12-0 N Series Скачать руководство пользователя страница 91](http://html1.mh-extra.com/html/axing/mk-12-0-n-series/mk-12-0-n-series_operation-instructions-manual_3036761091.webp)
2022-07-27 | Technical improvements, changes in design, printing- and other errors reserved.
15
Slide the compact headend into the 19 "rack.
Screw the compact headend with four screws (2).
Install the device in compliance with the safety regulations defined by the EN 60728-11 standard.
2.4.
Equipotential bonding
The device must be connected to the equipotential bonding according to EN 60728-11. Use the
equipotential bonding connection at the device.
To connect the outer conductor of the coaxial cable to the equipotential bonding, use e.g., QEW earthing
angles or CFA earth connection blocks at the inputs and output.
2.5.
Power supply
The headend has a built-in power supply unit. Connect the headend to a mains socket using the enclosed
mains cable.
2.6.
RF Installation
The input levels for the DVB standards must be complied with (see Chapter 7 on page 70).
2.6.1.
Connection to DVB-S/S2/S2X
Multiswitches as input distributors (recommended)
Multiswitches can be used as input distributors. The advantage of this solution is that you can set both the
polarization and the satellite via the user interface. Changes in the list of programs can be made using remote
maintenance, so that it is not necessary to change or modify the input distribution on site.
Direct connection to the LNBs
The devices have a remote supply voltage for the LNB and DiSEqC 1.0 functionalities at the inputs. The inputs
can be connected directly to the LNB.