Fill level
The data rate of the sender may vary depending on the image contents and on the transmission quality. To
ensure an undisturbed reception, a reserve must absolutely be observed.
We recommend you to set the maximal fill level to 90%.
If the current fill level exceeds the maximal fill level, it may cause image disturbances, e.g. mosaic images.
If the net data rate of the signal exceeds the net data rate of the output channel, the modulator overflows. This
overflow leads to disturbances. If the modulator overflows, the status LED on the front side of the device lights
in red.
Filtering the programmes reduces the net data rate of the input signal. Subsequently, the net data rate of the
output signal is also reduced. The data rate depends furthermore on:
•
channel bandwidth (7 or 8 MHz)
•
error correction rate (FEC)
•
modulation rate
•
guard interval
•
transmission mode
Selected Programmes
The programme table SELECTED PROGRAMS shows the programmes that were activated in phase 2.