Network Mode
Manual
Auto
MY16
MY8
The first DIP switch in block SW9 sets the network to Auto Mode when in the down position.
Auto Mode provides 64 total channels/Slots at 44.1 or 48kHz, and 32 total channels/Slots at 88.2 or 96kHz. Cables
can be connected to any available A‑Net port.
Manual Mode provides 64x64 total channels/Slots at 44.1 or 48kHz, and 32x32 total channels/Slots at 88.2 or
96kHz. The user must connect cables to specific A‑Net ports and route data to/from them as required by the
application. Manual Mode is ideal for high channel count systems that have clearly defined directional needs
such as a 64 x 16 digital snake. Remember that Manual Mode systems cannot be connected to a PC and controlled
from Pro64 Network Manager software.
Although the Pro64 network can operate at sample rates higher than 96kHz, Yamaha devices cannot. The Pro64
176.4 and 192kHz sample rates are not available when using a 6416Y2 card in a Pro64 network.
MY8 and MY16 Modes
Switch block SW8 contains the setting for Yamaha’s MY8 and MY16 Modes. MY16 Mode provides 16‑channel
operation at 44.1/48kHz sample rates, while the MY8 Mode provides 8‑channel operation when using higher
sample rates (88.2/96kHz) or when installing the 6416Y2 card in MY8‑only devices such as the PM1D digital
console at 48kHz.
Set DIP switch #10 in block SW8 to the up position (as seen in the diagram above) for 16‑channel operation at
44.1/48kHz.