Baud Rate Table
Use the following table to set baud rates for DIP switches 5‑8 in Switch Block SW4. The down position is
off
and
the up position is
on
for each DIP switch.
Baud Rate
DIP Switches in Block 4 (SW4)
8
5
6
7
8
1200
off
off
off
off
2400
on
off
off
off
4800
off
on
off
off
7200
on
on
off
off
9600
off
off
on
off
14400
on
off
on
off
19200
off
on
on
off
28800
on
on
on
off
38400
off
off
off
on
57600
on
off
off
on
31250
(MIDI)
off
on
off
on
The individual DIP switches in each Switch Block are numbered 1‑8, from left to right.
ON
ON
ON
ON
ON
ON
SW7
SW8
SW3
SW9
SW4
SW1
SW2
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
This example shows Switch Block SW4set for a baud rate of 57600 with 8 data bits. (DIP switch handles shown in black).
P
N
ote
:
The setting shown above for RS‑232 communication (baud rate and data bits) is required each time a
6416Y2 card has its firmware updated. To simplify the firmware update process, you can leave the DIP
switches in the positions shown.
The pinout of the RS‑232/422 jack on the 6416Y2 card appears later in this document. See page 70 for more
information.