DIP Switches
There is one 12‑position DIP switch block on the front panel of the 6416Y2, referred to as SW7 in the diagrams
that follow. Note the mounting direction of the DIP switches; to activate a switch on SW7, move it to the
down
position. The default setting for all switches in this block is
up
.
In this diagram, channels 7-8, 13-14, and 15-16 are stereo linked. This 6416Y2 is also the network Control Master.
DIP switch handles are indicated in black.
Clock and Control DIP Switches
Within front panel DIP Switch Block SW7 is a group of four system‑level DIP switches. These control the system
lock via password, 6416m or AllFrame preamp remote control via m‑control, firmware update status, and Control
Master vs. Slave status respectively.
Switch
Function Off (up)
Function On (down)
1‑8
Single channel control
Stereo Link per channel pair:
1‑2, 3‑4, etc.
9
System Unlocked
System Locked
10
m‑control Off
m‑control On
11
Local Code Update Off
(This switch is scanned only
at power up.)
Local Code Update Active
12
Slave Device
Control Master
22
c
ard
c