52
m
-
control
Control Group
DIP Switch 7
DIP Switch 8
1
Down
Down
2
Up
Down
3
Down
Up
4
Up
Up
The Channel/Slot Control settings are separate from the audio I/O setup (including A‑Net Transmit and Receive
settings). This parameter sets up remote control communications for all 6416Y2 cards installed in the same
console. Each 6416Y2 card needs its A‑Net Transmit and A‑Net Receive range properly configured in order to get
the desired results for your application.
Pad Mode
When using m‑control with Pro64 remote controllable mic preamps (as found in the 6416m and AllFrame) there
are user‑selectable options that control how the 24dB pad built into the remote preamps operate. Two choices
are available: Auto Pad and Manual Pad.
Pad Mode options in the Card Configuration dialog box
Choose Auto Pad to allow the remote control commands coming from the Yamaha device to automatically turn
the Pro64 mic preamp’s pad on and off as needed. This mode provides the widest range of gain settings for both
mic‑ and line‑level audio sources by combining the 56dB range of the preamp with the 24dB pad for a total 80dB
gain range. Note that the pad circuitry is in the analog domain for optimal audio fidelity. When the pad is engaged