The following examples show 6416Y2 card settings that can be used as starting points for creating a system.
Note that each diagram shows settings required when the cards are programmed manually using their on‑board
DIP switches. The process can be simplified by using Pro64 Network Manager software. Simply set the card for
Managed Mode and then program the I/O routing from within the Pro64 Network Manager software.
48 x 16 Digital Snake
The examples below show a three‑card digital snake in Auto Mode set to receive Slots 1‑48 from the network and
transmit Slots 49‑64 from the console into the Pro64 network.
Card #1 will be used to route return signals from the console back into the Pro64 network for amp/speakers or
monitors via Slots 49‑64. Only this card will have Slots activated, as seen in blocks SW1 and SW2.
Card 1 of 3
ON
ON
ON
ON
ON
ON
SW7
SW8
SW3
SW9
SW4
SW1
SW2
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
49-56 ON
57-64 ON
R
ec
eiv
e 1-16
Tr
ansmit 49-64
MY16
The first 6416Y2 card receives Slots 1-16 transmits Slot 49-64.
If you need less than 16 channels from the Yamaha device to be transmitted into the Pro64 network Slots, simply
change the appropriate DIP switches in blocks SW1 and/or SW2. For example, to transmit only 8 total channels
from the Yamaha console to the Pro64 network, move all DIP switches in block SW2 to the down position. Those
Slots are then available to be used by other Pro64 input devices within the network.