Figure 24: TWX670 Lightning Sensor Strike Test Pattern
Installation Manual
P/N 600-00175-000 Rev 04
Post-Installation Check
- 71 -
6.2 Electro-Magnetic Interference (EMI) Check
The EMI check verifies that there is no electrical interference between the EX500/EX600 MFD and
other electronic systems installed in the aircraft. Operating the MFD should not result in Nav flags,
constant location lightning strikes from the lightning sensor, noise on COMM channels, or other
phenomena.
●
COM Radios
—Scan through radio channels to ensure there is no interference caused by the
MFD. Check random frequencies from 118.00 MHz through 136.975 MHz as well as your local
ground and tower frequencies to ensure there is no break in squelch due to the installation.
●
GPS
—Ensure that correct position is displayed and that there is no change in satellite signal
strength with the MFD powered on and off.
●
Autopilot
—Ensure that autopilot Self Test passes OK with the MFD powered on.
●
Other Instruments
—Verify there is no adverse effect on other instruments with the MFD powered
on. Also verify that the MFD functions normally with all other electrical instruments on.
6.3 TWX670 Lightning Sensor Strike Test
With a TWX670 lightning sensor installed and set up, the Maintenance Mode page will have a
Lightning Strike Test
key which enables you to test the lightning sensor.
➤
To perform the Lightning Strike Test:
1.
On the Maintenance Mode page, press
Lightning Strike Test
.
2.
The Map page opens and displays the following strike test pattern.
3.
Verify the following:
■
The display shows four boxes (one at each of the four cardinal directions). A tight cluster of
test strikes within each of these boxes is a “pass” condition.
■
One or more boxes lacking a cluster of test strikes is an indication of a “fail” condition.
■
The display shows strikes from thunderstorms as well as test strikes; therefore it is not
unusual to see strikes outside the boxes. Look for a cluster of test strikes within each of the
boxes to make a pass/fail determination, not at the presence of strikes outside the boxes.
■
A poorly clustered set of test strikes, whether within or outside of the bounding box, may be an
indication of noise.
Содержание FlightMax EX500
Страница 1: ...Release 3 and Later Installation Manual 700 00007 700 00167 P N 600 00175 000 Rev 04 ...
Страница 2: ......
Страница 34: ...Installation Manual Wiring External Devices P N 600 00175 000 Rev 04 24 This page intentionally left blank ...
Страница 78: ...Installation Manual Map Heading Source Setup P N 600 00175 000 Rev 04 68 This page intentionally left blank ...
Страница 90: ...Installation Manual Service P N 600 00175 000 Rev 04 80 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 92: ...Installation Manual Service P N 600 00175 000 Rev 04 82 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 118: ...Installation Manual Radar Wiring P N 600 00175 000 Rev 04 108 This page intentionally left blank ...
Страница 122: ...Installation Manual P N 600 00175 000 Rev 04 112 This page intentionally left blank ...
Страница 123: ......