![Avidyne FlightMax EX500 Скачать руководство пользователя страница 65](http://html.mh-extra.com/html/avidyne/flightmax-ex500/flightmax-ex500_installation-manual_3031543065.webp)
Installation Manual
P/N 600-00175-000 Rev 04
MFD Feature Setup and Checkout
- 55 -
7.
Proceed to step N.
N.
Calibrate ROLL GAIN
1.
Set the tilt table for 10
o
roll right.
2.
Use the GAIN controls to set the GAIN POT /2 setting between 21- and 23-.
3.
Set the ROLL ANGLE field to 0.0 ±1.0
o
.
◆
To increment the value of the ROLL ANGLE, use the right inner knob to change the TILT
SETTING to between 5 and 10 UP. When the TILT SETTING is set to between 5 and 10
UP, the value of the ROLL ANGLE field will slowly increase.
◆
To decrement the value of ROLL ANGLE, use the right inner knob to change the TILT
SETTING to between 5 and 10 DOWN. When the TILT SETTING is set to between 5 and
10 DOWN, the value of the ROLL ANGLE field will slowly decrease.
◆
When you reach the desired setting, quickly adjust the TILT SETTING to above 10 UP to
lock in the setting.
4.
Set the tilt table for 10
o
roll left. Repeat Steps 2 and 3 of this section.
5.
Set the tilt table for 0
o
pitch and roll.
6.
Proceed to step O.
O.
Calibrate ROLL OFFSET
1.
Use the GAIN control to set the GAIN POT /2 setting between 14- and 16-.
2.
Check that the tilt table is set for 0
o
roll.
3.
Set the ROLL ANGLE field to 0.0 ±1.0
o
.
◆
To increment the value of the ROLL ANGLE, use the right inner knob to change the TILT
SETTING to between 5 and 10 UP. When the TILT SETTING is set to between 5 and 10
UP, the value of the ROLL ANGLE field will slowly increase.
◆
To decrement the value of ROLL ANGLE, use the right inner knob to change the TILT
SETTING to between 5 and 10 DOWN. When the TILT SETTING is set to between 5 and
10 DOWN, the value of the ROLL ANGLE field will slowly decrease.
◆
When you reach the desired setting, quickly adjust the TILT SETTING to above 10 UP to
lock in the setting.
4.
Set the tilt table to 10
o
roll right. The value should be 10.0R ±1.0
o
. If the value is out of range,
repeat step N.
5.
Set the tilt table to 10
o
roll left. The value should be 10.0L ±1.0
o
. If the value is out of range,
repeat step N.
6.
Set the tilt table to 0
o
roll. The value should be 0.0 ±1.0
o
. If the value is out of range, repeat
this step (step O.).
7.
Proceed to step P.
P.
Save Configuration
1.
Adjust the GAIN controls for a GAIN POT /2 setting to 4- or 5-.
2.
The FAULTS field will display GYRO.
Содержание FlightMax EX500
Страница 1: ...Release 3 and Later Installation Manual 700 00007 700 00167 P N 600 00175 000 Rev 04 ...
Страница 2: ......
Страница 34: ...Installation Manual Wiring External Devices P N 600 00175 000 Rev 04 24 This page intentionally left blank ...
Страница 78: ...Installation Manual Map Heading Source Setup P N 600 00175 000 Rev 04 68 This page intentionally left blank ...
Страница 90: ...Installation Manual Service P N 600 00175 000 Rev 04 80 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 92: ...Installation Manual Service P N 600 00175 000 Rev 04 82 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 118: ...Installation Manual Radar Wiring P N 600 00175 000 Rev 04 108 This page intentionally left blank ...
Страница 122: ...Installation Manual P N 600 00175 000 Rev 04 112 This page intentionally left blank ...
Страница 123: ......