![Avidyne FlightMax EX500 Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/avidyne/flightmax-ex500/flightmax-ex500_installation-manual_3031543055.webp)
Installation Manual
P/N 600-00175-000 Rev 04
MFD Feature Setup and Checkout
- 45 -
5.8.2 TAWS Communications Check (Messages)
If there is a communication or data error between the TAWS sensor and the MFD, one of the following
messages will display on the bottom of the screen.
Note:
If the EGPWS interface is operating properly, there will be no system status messages.
Table 19: TAWS Error Messages
Message
Meaning/Action
TAWS Failed
The system configuration is incorrect or one of the system components has failed.
■
Verify that the sensor is turned on and valid.
■
Verify system wiring.
TAWS Initializing
If message does not clear within 60 seconds, communication between the MFD and the
Terrain sensor has not been established.
■
Verify that the sensor is turned on and valid.
■
Verify system wiring.
■
See terrain sensor Installation and User’s Manual for troubleshooting guidance.
TAWS Not Communicating Indicates that the MFD is not receiving data from the Terrain sensor.
■
Verify that the sensor is turned on and valid.
■
Verify system wiring.
■
See TAWS sensor Installation and User’s Manual for troubleshooting guidance.
TAWS Display Unavailable The TAWS Sensor has declared itself inoperative.
■
Verify system wiring.
■
Verify that the sensor inputs to the TAWS are turned on and valid.
■
See TAWS sensor Installation and User’s Manual for troubleshooting guidance.
TAWS Sensor Self-Test
The TAWS Sensor is performing a Self-Test. The message will remain until the self-test
is finished.
■
Verify that the “Self-Test” mode has been not been selected at the separate TAWS
control panel.
■
Verify system wiring.
■
See TAWS sensor Installation and User’s Manual for troubleshooting guidance.
TAWS Inhibited
The TAWS sensor is in the “Inhibited” mode.
■
Verify that the “Inhibit” mode has been not been selected at the separate TAWS
control panel.
■
See TAWS sensor Installation and User’s Manual for troubleshooting guidance.
Содержание FlightMax EX500
Страница 1: ...Release 3 and Later Installation Manual 700 00007 700 00167 P N 600 00175 000 Rev 04 ...
Страница 2: ......
Страница 34: ...Installation Manual Wiring External Devices P N 600 00175 000 Rev 04 24 This page intentionally left blank ...
Страница 78: ...Installation Manual Map Heading Source Setup P N 600 00175 000 Rev 04 68 This page intentionally left blank ...
Страница 90: ...Installation Manual Service P N 600 00175 000 Rev 04 80 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 92: ...Installation Manual Service P N 600 00175 000 Rev 04 82 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 118: ...Installation Manual Radar Wiring P N 600 00175 000 Rev 04 108 This page intentionally left blank ...
Страница 122: ...Installation Manual P N 600 00175 000 Rev 04 112 This page intentionally left blank ...
Страница 123: ......