Installation Manual
Traffic Sensor Setup
P/N 600-00175-000 Rev 04
- 42 -
●
If you need to switch between types of installed traffic sensors, first change the traffic sensor type
to
None
, press
Save
, and restart the MFD. Then select the new traffic sensor type.
●
If you install a TAS600 Series or TCAD 9900BX traffic sensor using an RS-232 port, then the tail
number of other aircraft (equipped with Mode S transponders) or squawk codes will display on the
Map Page. Squawk codes and tail numbers cannot display if the traffic sensor is installed on an
ARINC 429 port.
●
If installing the MFD with dual Avidyne display units, such as an EX500/EX600 and a Multi-Hazard
Display (MHD), see the
Avidyne TAS600 Series Installation Manual
for wiring procedures and
information.
5.7.3 Traffic Sensor Checkout Procedures
RS232 Device Checkout
For the TAS600 Series or TCAD 9900BX, the MFD does not display the TCAD Self Test function.
Follow the checkout procedures described in the
Avidyne TAS600 Series Installation Manual
.
TAS (SkyWatch) Checkout
For TAS (SkyWatch), Self Test can only be performed from STANDBY mode and will return to
STANDBY mode upon successful completion of the Self Test.
➤
To perform a Self Test:
1.
With Traffic in Stand By, rotate the left knob and select the Setup Page.
2.
Select Traffic Self Test. The following actions occur:
■
The Map Page displays.
■
The Sensor Status indicates that the sensor is in “Test” and a Traffic test pattern appears on
the display.
If the Self Test fails, an error message is generated and displayed on the MFD screen. See the
SKY497 Installation Manual
for explanations and fault isolation procedures.
➤
To test the Sky497 installation:
1.
Use the alternate display procedure described in Appendix E of the
SKY497 Installation Manual
. A
terminal device using a RS-232 serial data cable is needed for these setup procedures.
2.
See Appendix D in the
SKY497 Installation Manual
for information about configuring the terminal
device. Any computer with RS-232 terminal emulation software (e.g., Procomm, HyperTerminal,
etc.) may be used as the terminal device.
TAS (Bendix/King) Checkout
➤
To test the TAS (Bendix/King) installation, verify correct communication by monitoring the Message
List on the Setup page for the following message: “Traffic Sensor Operating Normally”.
Note:
The MFD does not command the KTA870 in Self Test mode. Use the KTA870 control panel if
installed. See the
KTA870 Installation Manual
for fault isolation procedures.
TIS-G Checkout
Use a TIS transponder test set to test the combined installation of GTX-330 and the EX500/EX600. If
no test set is available, conduct operations in an area that supports TIS data and verify that data is
received and traffic is displayed.
Содержание FlightMax EX500
Страница 1: ...Release 3 and Later Installation Manual 700 00007 700 00167 P N 600 00175 000 Rev 04 ...
Страница 2: ......
Страница 34: ...Installation Manual Wiring External Devices P N 600 00175 000 Rev 04 24 This page intentionally left blank ...
Страница 78: ...Installation Manual Map Heading Source Setup P N 600 00175 000 Rev 04 68 This page intentionally left blank ...
Страница 90: ...Installation Manual Service P N 600 00175 000 Rev 04 80 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 92: ...Installation Manual Service P N 600 00175 000 Rev 04 82 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 118: ...Installation Manual Radar Wiring P N 600 00175 000 Rev 04 108 This page intentionally left blank ...
Страница 122: ...Installation Manual P N 600 00175 000 Rev 04 112 This page intentionally left blank ...
Страница 123: ......