MFD Feature Setup and Checkout
- 53 -
Note:
Failure to set any of the settings described in step E will prevent you from entering calibration
mode. If more than one radar indicator is installed in the system, all but one indicator must be
in the OFF or STBY position in order for the system to enter the calibration mode.
F.
Open the Aux Page and enter Maintenance Mode.
G.
Press
Radar Setup
to display the Radar Setup Page.
H.
From the Radar Setup Page, press
Calibration
to display the Calibration Page (see the Bendix/
King Installation Manual). When the system opens in calibration mode, all Fault fields will flash
briefly.
If the Fault fields do not flash, the Calibration Page is only open in display mode and you cannot
make changes. Make sure that you carefully followed the instructions in step E and try to enter
calibration mode again.
I.
Once you are in calibration mode, use the left outer knob to set ROLL TRIM to 0
o
.
J.
If desired, copy all displayed values to a notepad in case you need to recall a value that is
accidentally changed.
Note:
For information about how to adjust the radar settings, see the Bendix-King
Installation
Manual
.
➥
If using an ARINC 429 gyro, proceed to step Q.
K.
Calibrate 400 Hz REF GAIN
1.
Set the tilt table to 0
o
pitch and roll.
2.
Use the GAIN control to set the GAIN POT /2 setting between 28- and 30-.
3.
Set the 400 Hz REF field to 0.0 ±1.0
o
. To adjust the value:
◆
To increment the value of 400 Hz REF, use the right inner knob to change the TILT
SETTING to between 5 and 10 UP. When the TILT SETTING is set to between 5 and 10
UP, the value of he 400HzZ REF field will slowly increase.
◆
To decrement the value of 400 Hz REF, use the right inner knob to change the TILT
SETTING to between 5 and 10 DOWN. When the TILT SETTING is set to between 5 and
10 DOWN, the value of the 400HZzREF field will slowly decrease.
Содержание FlightMax EX500
Страница 1: ...Release 3 and Later Installation Manual 700 00007 700 00167 P N 600 00175 000 Rev 04 ...
Страница 2: ......
Страница 34: ...Installation Manual Wiring External Devices P N 600 00175 000 Rev 04 24 This page intentionally left blank ...
Страница 78: ...Installation Manual Map Heading Source Setup P N 600 00175 000 Rev 04 68 This page intentionally left blank ...
Страница 90: ...Installation Manual Service P N 600 00175 000 Rev 04 80 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 92: ...Installation Manual Service P N 600 00175 000 Rev 04 82 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 118: ...Installation Manual Radar Wiring P N 600 00175 000 Rev 04 108 This page intentionally left blank ...
Страница 122: ...Installation Manual P N 600 00175 000 Rev 04 112 This page intentionally left blank ...
Страница 123: ......