C - INSTALLATION
• The use of stops is mandatory (not provided)
This gate motor drive is a self-locking motorisation system. Your 2-panel gate must be equipped with a central
stop and side stops (not included).
The (central and side) stops must stop the gate without locking it. In other words, any mechanical lock (or
latch) and any tilting shoe base or stopper must be removed.
The installation of the side stops depends on the desired opening angle which depends on distance D (the
distance between the axis of the hinge and the inner side of the post).
D
D
positive distance D
negative distance D
view from above
view from above
post
post
If the positive distance
D
is greater than 190 mm or if distance
D
is negative, the configuration of the posts
must be adjusted.
Special cases
• If
D
>190mm and if the structure of the posts allows, the posts must be cut so that
D
’
is equal to
190mm.
D’
post
• If
D
<0mm, place a shim thick enough so that
D
’ is equal to 0mm.
D’