PROG and then + (not at the same time). The
panels should open. If a panel closes, reverse the
+ and - on the card.
To exit manual control mode, do a short press on
PROG and - at the same time.
SAFETY
Make sure that there is no one in the gate
movement area during the entire commissioning
period and the entire test period.
Starting self-learning
• Check that you are not in a prog menu by pressing
on prog 3 consecutive times.
• Press and hold the “
+
” button for 3 seconds.
The self-learning procedure may be interrupted at
any time by pressing OK.
Self-learning procedure
• The flashing light flashes.
•
Phase 0
: repositioning in central stop
Panel M2 closes up to the central stop.
Panel M1 closes up to the central stop.
•
Phase 1
: detection of side stops
Panel M1 opens up to the side stop.
Panel M2 opens up to the side stop.
•
Phase 2
: path detection
Panel M2 closes again up to the central stop
Panel M1 closes again up to the central stop.
•
Phase 3
: learning opening and closing
Panel M1 starts to open, gradually accelerating.
Panel M2 starts to open, gradually accelerating, 2.5
seconds (or more depending on the setting, see
MENU 3) after M1.
The panels reach their opening stops.
Panel M2 starts to close, gradually accelerating.
Panel M1 starts to close, gradually accelerating.
The panels reach the central stop (with a difference
of 2.5 seconds or more depending on the setting,
see MENU 3)
Error during self-learning
If self-learning does not work as described above
and stops earlier than expected (the motors and
the flashing light stop), some of the red LEDs
will be on or flashing, and others will be off. The
configuration of the red LEDs that are on provides
an error code allowing the installer to determine the
source of the incident that has occurred.
Below is a table indicating the self-learning error
codes:
: LED off
: LED on
: Flashing LED light
Make sure not to confuse the self-learning
error codes with error codes of events that
may occur during normal operation and
which are indicated in the same way by a
combination of red LEDs that are on / off /
flashing.
(See page 47)
L1
L2
L3
L4
Description
In phase 0, panel M1 did
not arrive at a stop after
closing for 60s, cable
section too weak?
In phase 0, panel M2 did
not arrive at a stop after
closing for 60s, cable
section too weak?
In phase 0, motor M1
was not detected (not /
incorrectly connected?).
In phase 0, motor M2
was not detected (not /
incorrectly connected?).
In phase 1, motor M1
reached the stop after
opening for less than 3s:
reduce the speed.
In phase 1, motor M2
reached the stop after
opening for less than 3s:
reduce the speed.
In phase 1, panel M1 did
not reach a stop after
opening for 60s or cable
section too weak?
D - BEGINNING OPERATION