7.6 - BACKUP BATTERY (OPTIONAL)
It is possible to connect a backup battery to perform some manoeuvres in the event of power failure.
• Type of battery: NiMH
• Battery voltage: 24V
• Configuration: 20xAAA / 800mAh
• After connecting the battery, it will charge for up to 48H.
PRO
G
OK
L0
L1
L2
L3
L4
7.7 - SOLAR POWER KIT (OPTIONAL)
Warning: do not connect a solar power supply at the same time as the mains power supply.
The 24V solar power kit is plugged into the same connector as the backup battery. The solar power kit (which
already has a battery) and a backup battery cannot be connected at the same time.
For installation, refer to the solar power kit instructions.
When a solar power kit is connected, if you press the “OK” button on the electronic card, the number of red
LEDs that light up indicates the battery charge level.