![Avaya G650 Скачать руководство пользователя страница 234](http://html1.mh-extra.com/html/avaya/g650/g650_installation-instructions-manual_3027012234.webp)
Installing and wiring telephone power supplies
234
Installing the Avaya S8700 Media Server with an Avaya G650 Media Gateway
December 2003
3
Plug the battery cord into the power supply’s right rear receptacle. The rear receptacle is indicated
on the right label.
Installing the expanded power distribution
unit
A second power distribution unit can be installed to provide power to additional devices.
CAUTION:
Total power cannot exceed 275 watts. The maximum ISDN terminal mixture is 24, 7500-
series and 24, 8500-series terminals.
The maximum DCP terminal mixture is 24, 7400-series and 24, 8400-series or 64, 8400-
series terminals.
The expanded power distribution unit kit contains:
•
One 1146B2 Power Distribution Unit
•
One “T” Cable
•
Two #8-32 x 1/2-in. Shoulder Screws
•
One #8-32 x 1-in. Screw
•
One spacer bracket
See
Figure 93, Expanded power distribution unit,
on page 232 while installing the power distribution
unit.
1
Set the spacer bracket onto the mounting plate and secure with the #8-32 x 1/2-inch shoulder
screws. The spacer bracket is not shown in the figure but is installed behind the top power
distribution unit.
2
Slide the keyhole slots in the power distribution unit over the shoulder screws.
3
Insert the #8-32 x 1-inch screw through the distribution unit, through the spacer bracket, and into
the plate. The mounting hole is located just above the wire clip. Tighten the screw securely.
4
Set the battery back-up switch to the 1-32 (down) position.
5
Power-down the 1145B2 unit as described on the label on the side of the unit.
6
Remove the output power cable between the 1145B2 and the 1146B2 units. The cable will not be
reused.
7
Connect the P1 connector end of the “T” cable to the bottom power distribution unit. Connect the
P2 connector to the top distribution unit. Connect the P3 connector to the 1145B2.
8
Power-up the 1145B2 as described on the label on the side of the unit.
Table 30: Back-up battery rating
Battery
Rating
1148B
2.5 amp-hours
1149B
5 amp-hours
1147B
8 amp-hours