Industrial Managed
Ethernet Switch – EH9711
User Manual
Page
55
of
223
Label
Description
Factory Default
packets are normal.
InErrors
: The number of inbound packets that contained errors preventing
them from being deliverable to a higher-layer protocol.
InUnknownProtos
: the number of the inbound packets that were discarded
because of the unknown or un-support protocol.
OutOctets
: The number of octets transmitted out of the interface , including
framing characters.
OutUcastPkts
: The number of uni-cast packets that request to transmit.
OutNUcastPkts
: The number of broad-cast and multi-cast packets that
request to transmit.
OutDiscards
: The number of outbound packets that are discarded event the
packets is normal.
OutErrors
: The number of outbound packets that could not be transmitted
because of errors.
OutQLen
: The length of the output packet queue (in packets).
Sample Type
The method of sampling the selected variable and calculating the value to be
compared against the thresholds, possible sample types are:
Absolute
: Get the sample directly.
Delta
: Calculate the difference between samples (default).
Delta
Value
The value of the statistic during the last sampling period.
0
Start-up Alarm
The method of sampling the selected variable and calculating the value to be
compared against the thresholds, possible sample types are:
Rising
Trigger alarm when the first value is larger than the rising threshold.
Falling
Trigger alarm when the first value is less than the falling threshold.
RisingOrFalling
Trigger alarm when the first value is larger than the rising
threshold or less than the falling threshold (default).
RisingOrFalling
Rising Threshold
Rising threshold value (-2147483648-2147483647).
0
Rising Index
Rising event index (0-65535). If this value is zero, no associated event will
be generated, as zero is not a valid event index.
0
Falling Threshold
Falling threshold value (-2147483648-2147483647)
0
Falling Index
Falling event index (0-65535). If this value is zero, no associated event will
be generated, as zero is not a valid event index.
0
2.5.1.17
RMON Event
Figure 2.50 shows
RMON Event Configuration
. It displays RMON event table. The entry index key is ID for RMON event
table. Click
Add New Entry
button to add a new RMON event entry to the table as shown in Figure 2.50. Table 2.32 describes
the column labels of the RMON alarm table. Please click on the
Save
button afterwards for a change to take effect, or click
Reset
button to undo any changes made locally and revert to previously saved values.
Figure 2.50 Webpage
to Configure RMON Event