2.5.1.12
SNMP Views
Figure 2.43 shows SNMPv3 View Configuration webpage. It contains SNMPv3 view table. The entry index keys are
View
Name
and
OID Subtree
. Click
Add New Entry
button to add a new view entry to the table. Table 2.27 describes the column
labels of the SNMPv3 view table. Please click on the
Save
button afterwards for a change to take effect, or click
Reset
button
to undo any changes made locally and revert to previously saved values.
Figure 2.43 Webpage to Configure SNMP Views
Table 2.27 Descriptions of SNMP Views
Label
Description
Factory
Default
Delete
Check to delete the entry. It will be deleted during the next save.
View Name
A string identifying the view name that this entry should belong to. The allowed string
length is 1 to 32, and the allowed content is ASCII characters from 33 to 126.
Null
View Type
Indicates the view type that this entry should belong to. Possible view types are:
included
: An optional flag to indicate that this view subtree should be included.
excluded
: An optional flag to indicate that this view subtree should be excluded.
In general, if a view entry's view type is 'excluded', there should be another view entry
existing with view type as 'included' and it's OID subtree should overstep the 'excluded'
view entry.
included
OID Subtree
The OID defining the root of the subtree to add to the named view. The allowed OID
length is 1 to 128. The allowed string content is digital number or asterisk (*).
Null
2.5.1.13
SNMP Access
Figure 2.44 shows SNMPv3 Access Configuration webpage. It contains SNMPv3 access table. The entry index keys are
Group
Name
,
Security Model
and
Security Level
. Click
Add New Entry
button to add a new access entry to the table. Table 2.28
describes the column labels of the SNMPv3 access table. Please click on the
Save
button afterwards for a change to take effect,
or click
Reset
button to undo any changes made locally and revert to previously saved values.