Figure 3.34 Webpage to Monitor RMON Alarm Overview
Table 3.28 Monitoring Descriptions of RMON Alarm Overview
Click
Add New Entry button
to add a new access management entry. Click
Save button
to save changes. Click
Reset
button
to undo any changes made locally and revert to previously saved values.
3.5.3.4
RMON Event
Configure RMON Event table on this page. The entry index key is ID.
Label
Description
Delete
Check to delete the entry. It will be deleted during the next save.
ID
Indicates the index of the entry. The range is from 1 to 65535.
Interval
Indicates the interval in seconds for sampling and comparing the rising and falling threshold. The
range is from 1 to 2^31-1.
Variable
Indicates the particular variable to be sampled, the possible variables are:
InOctets:
The total number
of octets received on the interface, including framing characters
. InUcastPkts:
The number of uni-
cast packets delivered to a higher-layer protocol.
InNUcastPkts:
The number of broad-cast and multi-
cast packets delivered to a higher-layer protocol.
InDiscards:
The number of inbound packets that are
discarded even the packets are normal.
InErrors:
The number of inbound packets that contained
errors preventing them from being deliverable to a higher-layer protocol.
InUnknownProtos:
the
number of the inbound packets that were discarded because of the unknown or un-support protocol.
OutOctets:
The number of octets transmitted out of the interface, including framing characters.
OutUcastPkts:
The number of uni-cast packets that request to transmit.
OutNUcastPkts:
The number
of broad-cast and multi-cast packets that request to transmit.
OutDiscards:
The number of outbound
packets that are discarded event the packets are normal.
OutErrors:
The number of outbound packets
that could not be transmitted because of errors.
OutQLen:
The length of the output packet queue (in
packets).
Sample Type
The method of sampling the selected variable and calculating the value to be compared against the
thresholds, possible sample types are:
Absolute:
Get the sample directly.
Delta:
Calculate the
difference between samples (default).
Value
The value of the statistic during the last sampling period.
Startup Alarm
The method of sampling the selected variable and calculating the value to be compared against the
thresholds, possible sample types are:
Rising
Trigger alarm when the first value is larger than the
rising threshold.
Falling
Trigger alarm when the first value is less than the falling threshold.
RisingOrFalling
Trigger alarm when the first value is larger than the rising threshold or less than the
falling threshold (default).
Rising Threshold
Rising threshold value (-2147483648-2147483647).
Rising Index
Rising event index (1-65535).
Falling
Threshold
Falling threshold value (-2147483648-2147483647)
Falling Index
Falling event index (1-65535).