Table 2.7 Description of Time Zone Configuration
Label
Description
Time
Zone
Lists various
Time Zones
worldwide. Select appropriate Time Zone from the drop down and click Save to
set. The
'Manual Setting'
options is used for the specific time zone which is excluded from the options list.
Hours
Number of hours offset from UTC. The field only available when
Time Zone
is set to
Manual Setting
.
Minutes
Number of minutes offset from UTC. The field only available when
Time Zone
is set to
Manual Setting.
Acronym
User can set the acronym of the time zone. This is a User configurable acronym to identify the time zone.
(Range: Up to 16 characters)
Notice the string '' is a special syntax that is reserved for null input.
Table 2.8 Description of Daylight-Saving Time Configuration
Label
Description
Daylight Saving
Time
This is used to set the clock forward or backward according to the configurations set below for a
defined Daylight-Saving Time duration.
- Select '
Disable
' to disable the Daylight-Saving Time configuration.
- Select '
Recurring
' and configure the Daylight-Saving Time duration to repeat the configuration
every year.
- Select
'Non-Recurring
' and configure the Daylight-Saving Time duration for single time
configuration.
(Default: Disabled)
Recurring Configuration
Start Time
settings
Week
- Select the starting week number.
Day
- Select the starting day.
Month
- Select the starting month.
Hours
- Select the starting hour.
Minutes
- Select the starting minute.
End time settings
Week
- Select the ending week number.
Day
- Select the ending day.
Month
- Select the ending month.
Hours
- Select the ending hour.
Minutes
- Select the ending minute.
Offset settings
Offset
- Enter the number of minutes to add during Daylight Saving Time. (Range: 1 to 1439)
Non-Recurring Configuration
Start Time
settings
Month
- Select the starting month.
Date
- Select the starting date.
Year
- Select the starting year.
Hours
- Select the starting hour.
Minutes
- Select the starting minute.
End Time
settings
Month
- Select the ending month.
Date
- Select the ending date.
Year
- Select the ending year.
Hours
- Select the ending hour.
Minutes
- Select the ending minute.
Offset settings
Offset
- Enter the number of minutes to add during Daylight Saving Time. (Range: 1 to 1439)
2.1.5
Log
Figure 2.12 shows
System Log
configuration
setting
webpage. System Log or syslog keeps records of messages or events
that are related to the overall functionalities of the managed switch. Here the users can enable how the log will be delivered to
other system. It can be sent to a remote log server. Select
Enabled
from the drop-down list of the
Server Mode
field if users
want the system log to be saved in the remote log server, or select
Disabled
to disable server mode operation.
The users need to select the log level and provide the IP address of a remote log server. Please click on the
Save
button after
finishing the setup or
Reset
button to disregard all changes made locally and revert to previously saved values. Table 2.9
describes the details of parameters setting for the system log. Type of syslog level include: Error, Warning, Notice, and