Industrial Managed
Ethernet Switch – EH9711
User Manual
Page
53
of
223
Figure 2.45 Webpage
to Configure RMON Statistics
Figure 2.46 Adding New Entry to RMON Statistics Configuration
Table 2.29 Descriptions of RMON Statistics
Label
Description
Factory Default
Delete
Check to delete the entry. It will be deleted during the next save.
ID
Indicates the index of the entry. The range is from 1 to 65535.
Null
Data Source
Indicates the port ID which wants to be monitored. If in stacking switch, the
value must add 1000000*(switch ID-1), for example, if the port is switch 3 port
5, the value is 2000005.
.1.3.6.1.2.1.2.2.1.1.
0
2.5.1.15
RMON History
Figure 2.47 shows
RMON
(Remote Network Monitoring)
History
Configuration. It displays RMON history table. The entry
index key is
ID
for RMON history table. Click
Add New Entry
button to add a new RMON history entry to the table as shown
in Figure 2.48. Table 2.30 describes the column labels of the RMON Statistics table. Please click on the
Save
button afterwards
for a change to take effect, or click
Reset
button to undo any changes made locally and revert to previously saved values.
Figure 2.47 Webpage
to Configure RMON History