2.5.1.8
SNMP Trap Sources
This page provides
SNMP Trap Source configurations
. A trap is sent for the given trap source if at least one filter with filter
type included matches the filter, and no filters with filter type excluded matches. Figure 2.37 shows the webpage when there
is no entry in the trap source configurations. When users click on the Add New Entry button, the webpage will be updated to
Figure 2.38. The users can select Name for trap source from the drop-down list and select the type from the second drop-down
list. Then, enter the
Subset OID
in the text field. Click on the
Save
button to save the changes or click on the
Reset
button to
undo any changes made locally and revert to previously saved values. Table 2.23 provides descriptions of the SNMP Trap
Source Configurations.
Figure 2.37 Webpage to Configure SNMP Trap Sources
Figure 2.38 Adding New Entry to SNMP Trap Sources
Table 2.23 Description of SNMP Trap Source Configurations
Label
Description
Delete
Check to delete the entry. It will be deleted during the next save.
Users are allowed to delete each entry
separately.
Name
Indicates the name for the entry. Selectable from the following list.
- coldStart
- warmStart
- linkUp
- linkDown
- newRoot
- topologyChange
- psecTrapInterfaces
Type
The filter type for the entry. Possible types are:
included
: An optional flag to indicate a trap is sent for the given trap source is matched.
excluded
: An optional flag to indicate a trap is not sent for the given trap source is matched.
Subset OID
The subset OID for the entry. The value should depend on the what kind of trap name. For example, the
ifIdex is the subset OID of linkUp and linkDown. A valid subset OID is one or more digital number (0-