Installation & Servicing instructions ATAG iC-Range
36
12.1 Controls and explanation of the functions
Hot water
Setting the hot water temperature:
Briefl y press + or – ; the display will show the fl ashing preset value;
Briefl y press + or – to change the set value. Each change becomes active directly.
Hot water program OFF: Press – until the lowest value is reached and then press – again.
The display is showing - - .
Switching on works in reverse order.
Central heating
Setting the CH water temperature:
Briefl y press + or – ; the display will show the fl ashing preset value;
Briefl y press + or – to change the set value. Each change becomes active directly.
CH program OFF: Press – until the lowest value is reached and then press – again. The
display is showing - - .
Switching on works in reverse order.
Boiler information
Requesting current data:
Press the eco-button for 6 seconds in order to obtain the following value using the scroll
buttons:
A0 Flow water temperature in °C
A1 Return water temperature in °C
A2 DHW temperature in °C
A3 T-set temperature (calculated) in °C
A4 Flue gas temperature (only if a fl ue gas sensor is connected) in °C
A5 Outside temperature (only if an outside sensor is connected) in °C
A6 Water pressure in bar
A7 DHW fl ow in l/min.
A8 Ionisation current in A.
A9 rpm of fan (x100)
To return to the standard view press ESC.
Reset button
The reset button allows the boiler to restart if an error has occurred.
In case of an error the
symbol is displayed with a XXX code.
In other cases the Reset button does not function and will not respond to operation.
See chapter 17 for a brief overview of codes
Ancillary functions:
Both + buttons = Commissioning-mode for checking the CO
2
CH + button = OK (confi rm)
DHW Button: Scroll function
(‘scrolling’ through parameters)
CH – button = ESC function
(back to standard display)
Both – buttons: Pump continuous on/off
OK
ESC
sc
ro
ll
Содержание iC 24
Страница 33: ...Installation Servicing instructions ATAG iC Range 33 Figure 10 7 a 10 9 Electrical diagram...
Страница 56: ...Installation Servicing instructions ATAG iC Range 56 Annex C Short parts list...
Страница 57: ...Installation Servicing instructions ATAG iC Range 57...
Страница 58: ......
Страница 59: ......
Страница 60: ......
Страница 61: ......