Installation & Servicing instructions ATAG iC-Range
32
10.1 One controller, OpenTherm and BUS connection (blue)
The blue BUS connection can only be used for the ATAG ONE controller (CT000111), an OpenTherm
controller or the ATAG 7 Day Two Channel Plug-In Digital Programmer (CT200002).
10.2 Room thermostat volt free connection (black)
A volt free on / off room thermostat or a programmable room thermostat with volt free connections can be
wired to the black volt free room thermostat connector position.
The ATAG 7 day, Single Channel Digital Wireless Programmer and Room Thermostat (CT200001) or ATAG
24 hour, Single Channel Mechanical Wireless Programmer and Room Thermostat (CT100002) both come
with the receiver fi tted within a replacement facia panel for the front of the boiler and their volt free plug
connects into this Room thermostat volt free connections (black).
10.3 ATAG Central Heating volt free timer connection (white)
The ATAG 24 hour, Single Channel Plug-in Mechanical Timer (CT100001) comes fi tted within a replacement
facia panel for the front of the boiler and the volt free plug connects into this Central Heating volt free
connection (white).
This enables the boiler to be available for heating during the set times of the timer.
A volt free room thermostat is still required to be connected to the Room thermostat volt free connection
(Black) to create a demand for heat via a room stat.
10.4 ATAG Hot Water volt free timer connection (white)
This connection enables and disables the boiler to provide hot water during the set times if a specifi c timer
was connected.
10.5 DHW sensor connection (yellow)
N/A not applicable.
10.6 ATAG Outside sensor (orange)
When a weather compensation sensor (supplied with the boiler) is used, the two wires from the outside
sensor get wired into the plug supplied with the sensor and connect onto the orange connector position.
10.7 230V Control Block (230V live output)
If a live, neutral or earth wire is required for an external clock/programmer these can be taken from the (L)
live, (N) Neutral or (E) earth 230V live output connections on the 230v control terminal block.
If an external 230V clock/programmer is used, then a switched live is required from the control(s) to connect
to the 230V control terminal block in position (SwL) Switched live to fi re up the boiler.
10.8 230V Control Block (SwL Switched live)
If a 230V room thermostat is used, then a switched live is required from the control(s) to connect to the 230V
control terminal block in position (SwL) Switched live to fi re up the boiler. This could be in series after the
clock/programmer to the room stat, then to SwL on the 230V control terminal block.
Содержание iC 24
Страница 33: ...Installation Servicing instructions ATAG iC Range 33 Figure 10 7 a 10 9 Electrical diagram...
Страница 56: ...Installation Servicing instructions ATAG iC Range 56 Annex C Short parts list...
Страница 57: ...Installation Servicing instructions ATAG iC Range 57...
Страница 58: ......
Страница 59: ......
Страница 60: ......
Страница 61: ......