9.8.1 Flue terminal locations
The terminal should be located where dispersal of combustion products is not unimpeded and with due
regard for the damage or discolouration that might occur to parts of the building in the vicinity (see fi g
9.8.1.c).
In certain weather conditions condensation may also accumulate on the outside of the air inlet pipe. Such
conditions must be considered and where necessary insulation of the inlet pipe may be required.
In cold and/or humid weather water vapour may condense on leaving the fl ue terminal. The eff ect of such
‘plumeing’ must be considered.
The terminal must not be located in a place where it is likely to cause a nuisance, where the terminal is less
than 2m (6.6ft) above a pavement or platform to which people have access (including) any balcony or fl at
roof. The terminal must be protected by a guard of durable material.
Where a terminal is fi tted below a window which is hinged at the top, and where the hinge axis is
horizontal, and the window opens outwards, the terminal shall be 1m below the bottom of the window
opening.
The fl ue must be terminated in a place not likely to cause a nuisance.
For horizontal fl ue terminal direct to the rear or side through the wall (only 1 bend
and 1 wall terminal) the terminal should be placed horizontal. The fl ue pipe inside
the terminal is fi tted in a 3 degrees angle to ensure the condensation water can run
back to the boiler. See fi gure 9.8.1.a.
For longer horizontal sections, the outlet system should always be fi tted on an
incline (52 mm/m = 3°) sloping down towards the boiler so that no condensation
water is able to accumulate in the outlet system. The chances of icicles forming on
the outlet is minimised by causing the condensation water to run back towards the
boiler. See fi gure 9.8.1.b.
Figure 9.8.1.a
Figure 9.8.1.b
Содержание iC 24
Страница 33: ...Installation Servicing instructions ATAG iC Range 33 Figure 10 7 a 10 9 Electrical diagram...
Страница 56: ...Installation Servicing instructions ATAG iC Range 56 Annex C Short parts list...
Страница 57: ...Installation Servicing instructions ATAG iC Range 57...
Страница 58: ......
Страница 59: ......
Страница 60: ......
Страница 61: ......