AT-LA500
–
U
SER MANUAL
R
ELEASE
3.4
–
JUNE
2009
75
Strobe
This panel allows assigning values to Digital Pattern Generator pins, read their status or setting
them in a high impedance state.
Strobe Vectors
It allows assigning a value to Vectors[15..0], to the Extended
Trigger signal and to Write RAM signals. By pressing the Strobe
button the output channels will change their logic levels to the
assigned ones.
Pods status
The Digital Pattern Generator can also operate in Sampler mode.
Channels change their behavior from outputs to inputs.
When the Read Pods Status button is pressed, the logic level of
each input can be examined in real time.
HiZ Strobe
By pressing the Set HiZ button all channels will go in a impedance
state
Buffer
0/1
Direction
It controls the direction of the output buffer 0 (Ch 17..0) and the
direction of the buffer 1(35..0). If Out is selected, the direction is
output (generation mode), if In the direction is input (acquisition
mode)
Extended Trigger
Extended trigger input enabled or disabled
Write RAM
Active high signal. If high (Enable), the AT-LA500 Pattern stores
the current channel value in the SRAM memory.